|
This Newsletter
was automatically translated by an internet translator machine from
French to English and the translation can show misuses of words which
can create funny things.
Thanks for your understanding.
Labomat News N°24
Already 3 years...
Since september 2000, our newsletter gives you all the informations
concerning our new products. The use of Internet and email is more and
more frequent now in our business. Each month, more and more of you
ask to join our mailing list. Our subscribers are very pleased to receive
our news on a two months basis.
The periodicity of our LabomatNews has been slightly disturbed these
last months.
And this is not because we have no news to announce !
This is in fact the masses of new products that block our journalistic
reactivity. Before announcement, we have to create commercial documentations,
french translations of operating manuals and brochures, prepare sales
support data sheets... And we have still so many documents to digitalize
!
The number of PDF documentations (Acrobat Reader) that we placed on
our web site and that we can send through Email is growning fast, but
we still have a lot to do...
|
|
|
Instruments
& Spécialités----
|
And now, the news...
COLOUR - VeriVide Colour
Accessment Cabinets
 |
Since the beginning of 2003, a new programmable
control panel replace the previous push-button controler. |
|
These new cabinets that we presented you in our January
2003 Labomat News brings variety of advanced features...
but even if the use of these cabinets is still simple, the way
to adjust parameters, automatic sequence and timers for life
lamp duration needs more attention. The English operating manual
is available, but for French speaking people, it is not so clear...
That's why Labomat have done its best to propose a French manual.
You can download here the PDF version of the CAC
VeriVide French operating manuals (but only if you enjoy
reading french technical documentations...). |
TABER
ABRASIMETER - Adapter for thick samples
 |
|
In accordance with the request of
the French Technical Center for wood and furnishing (C.T.B.A.),
Labomat and Taber have developped a new accessory feature to allow
abrasion resistance tests for samples up to 40 mm thick. This
one piece feature rise the abrading arms and nozzle hinge mountings
to garanty a correct right-left and front-back alignment. A set
of disks of different thicknesses is also delivered. These disks
can be placed on the turntable to accept thinner samples. |
We are at your disposal
for more informations. You can also contact Mr
LAIGLE, responsable of the CTBA Furnishing division laboratory
for technical discussion and recommendations.
Mr Laigle can also do tests on your samples. |
| CS0 Rubber wheels |
| These wheels are often used to support
S42 abrasive paper. After a reproductibility test campaign, it
has been shown that the hardness of these wheels can have an impact
on tests. That's why Taber decided to reduce the tolerance and
improve the quality of these wheels. The new CS0 wheels are now
identified with a silver sticker mentioning batch number. The
hardness is now 65 +/- 5 Shore A. Harder than the revious ones
(55 Shore A), they are more stable in time and are valid for 2
years. Each wheel is now also controlled for hardness and dimensions
before delivery. |
THICKNESS
- PosiTector 200 -
The new low cost Ultrasonic gauge
|
The brand new PosiTector 200
allows to measure the thickness of films on wood, concrete and
other non metallic substrates.
|
 |
The gauge uses the non
destructive ultrasonic method in conformity with ASTM D 6132 standard.
The rugged housing, identical to the PosiTector 6000 one, is solvent,
acid, oil, water and dust resistant. The PosiTector 200 uses a
large, easy-to-read LCD with menu-driven user interface. It is
easy to use with a 2-button operation. It can stores up to 1000
measurements, shows statistics and can be connect to a printer
or PC.
Range of measurements: 25 to 1000 µm |
TEMPERATURE
-HUMIDITY - Testo 177 Recorders
|
|
To avoid moisture on
walls or roofs that can appear because of faulty
structure or bad ventilation, real estate companies record
and memorize air humidity, air and surface temperature on
site on a long period of time. The display of the 177 recorder
shows instant datas. Up to 48000 measurements coming from
up to 25 different recorders can be collected, printed or
analysed with the Comsoft software. The battery life time
can reach 5 years.
|
XENON TEST
- Flat Array against Rotating Drum
| Old standards against innovative
new technologies
|
|
Rotating drum chamber attempts
to achieve uniformity of exposure conditions by revolving test
specimens in a corrousel-like fashion around the Xenon lamp.
This expensive system deduce space for samples and does not
reduce top-to-bottom variation. In a static array, such as the
Q-Sun Xenon Test Chamber, a flat, stationary specimen tray is
used. In the Q-Sun, the reflective chamber walls and the internal
reflectors on the lamp housings are designed to maximize irradiance
uniformity. Since the samples are placed horizontally, top-to-bottom
variations do not occur. |
|
The old standards have been revised,
and the new performance-based standards say that it is alright
to use innovative new technologies such as a static, flat-plane
specimen mounting system. The standards say it. Now
the data proves it. A new technical paper LX-5021 titled
"Xenon Arc Exposure results : Rotating & Static Specimen
mounting Systems compared" compares the results from a
serie of studies conducted using flat-array style and rotating
drum style equipment. Showing the data from almost 300 specimens
from nine separate material groups, the paper proves that remarkable
agreement is achievable between the two systems. Please ask
us to receive a copy of this paper. |
VISCOSITY
- New DV2+ Pro viscosimeter
|
The new improvement of the Programmable DV2+ to
the DV2+ Pro is quiet imperceptible but is of a great importance.
The RS232 data output is now bidirectional.
In standard use, we mean without computer and softwre, no changes
are visible except the color of the housing which is now blue
(it was grey). However, the new bidirectional output allows
the control of the viscosimeter by the computer and the use
of the sophisticated Rheoclac system. The new DV2+ Pro can now
work like a DV3. From the computer, the speed of rotation can
be fixed from 0.01 RPM to 200 RPM by speps of 0.1 RPM. That
means more than 2000 different speeds ! With the Small Sample
Adapter (coaxial geometry) you can now record many datas and
plot precise rheogram for exact analysis. You can also fix the
speed to reach specific shear rate (for exemple 10 s-1 or 100
s-1). That was not so easy in the past with only 54 speeds.
|
Dial reading Viscometer :
Change for a 10 speed system!
Since 1934, the good old dial reading
viscometer from Brookfield is still exactly the same or nearly.
However, certain spare parts are no longer available because
they are of too old technologies. This is the case for exemple
for the motor or the gearwheel system. When these parts are
faulty, we propose an upgrade for a step-by-step motor of new
technology. But it is not necessary for you to wait
that these pieces get faulty ! You can already replace
your old noisy 4 or 8 speeds motor by a new 10 speeds silent
motor! This change can give more possibilities to your present
viscometer, mainly if it is a LVF or RVF system.
|
 |
|
Practical seminars for Brookfield users
Our next seminars will take place in
our premises in Saint Denis the 04 décembre 2003.
Expected dates for 2004 (in our office) :
05 february 2004
01 april 2004
10 june 2004
14 october 2004
02 december 2004
|
| |
|
|
DECORATIVE
GLITTERS -
Our participation to modern art
| Our decorative glitters
has recently been used by a well-known artist from Paris, Mr
Vincent BEAURIN during an contemporary art exhibition at the
Fondation
Cartier. The exhibition called "Yanomami, the spirit
of the forest" was the result of the meeting between international
contemporary artists and eleven shamans from Watoriki, a yanomami
village in Bresil. |
Signs
Polystyrene, wood
and polyester structure. |
|
|
For Vincent BEAURIN :
"These signs can be compared to the visions of the yanomami
shamans. Their skins, covered with glitters, echoes the magnificent
and sparkling brightness of the animal ancestor spirits." |
EXHIBITIONS
|
MIDEST 2003
|
| The MIDEST 2003, the world's leading show for
industrial subcontracting, will take place in Paris Nord Villepinte
from the 18 to the 21 november 2003. On more than 70000 m2,
2200 exhibitors from 35 differents country will present new
innovative solutions to respond to the recent industrial challenges.
The program of this exhibition is on the Midest
Internet site .
Visit us there : 6 L 101
|
|
|
EUROFINISH 2003
|
| The European exhibition for
Surfaces Treatments Eurofinish 2003 took place in Gand in Belgium
the 8, 9 and 10 of october 2003. We had there the opportunity
to meet a lot of visitors.
|
|
We hope that you liked reading our newsletter and it provided information
of particular use to you. We await your comments and suggestions.
Best regards.
Stéphane Gellée
Contact Email: info@labomat.com
You always have the possibility to consult our previous
News : july 2003
|